|
Installing and Removing TabletWorks in
Windows 95/NT
1. Installing the TabletWorks driver.
NOTE: If you are installing from a CD-ROM, skip to step B.
A. Installing a downloaded driver.
1. Click on the "Start" button.
2. Click on the "Run" option.
3. In the command line box, type the path of the driver and click
"OK".
Example: C:\windows\temp\tw95v51.exe
4. Go to section C.
B. Installing from a CD-ROM.
1. Double-click the "My Computer" icon.
2. Double-click the "CD-ROM" icon.
3. Double-click the "Startme" icon.
4. Go to section C.
C. Driver installation.
1. Click on "Setup".
2. Click on "Install".
3. Select the brand of tablet you have (CalComp or Summagraphics).
NOTE: If you are using a Summagraphics tablet, you will be prompted for
the following:
Tablet Model
COM port
Pointing Device
Operating Mode
NOTE: UIOF will be the default operating mode for most Summagraphics
tablets.
4. You will be asked where you would like the driver to be installed on your
system. C:\windows\CalComp is the default.
5. After the files have been copied to your system, you will be prompted to restart your computer.
NOTE: For the CalComp Legacy tablets listed below, do not restart your
system immediately. Go to section D.
Wiz 25xxx
23xxx(DrawingBoard)
91xxx 95xxx
Notepad
NOTE: If you choose to restart your computer immediately a temporary file
will be left on your computer in the c:\windows\temp directory.
Example: C:\windows\temp\WZS*.TMP
If you elect not to restart immediately,
the temporary file will be deleted automatically. You will
then have to restart
your computer manually.
D. CalComp Legacy Tablets
1. If you have not restarted your system after installing the driver, follow steps c through h below.
2. If you did restart your system after installing the driver, follow steps a through h below.
a. When the computer restarts, you
will see the following error message on the
screen:
cc95drv
Calcomp Driver
could not find tablet! ...
Press any key to
continue
b. Press any key to continue booting
into Windows95/NT
c. Double-click on the TabletWorks
Control Panel icon. The following message
will appear:
Wintab™ support
not found or imcompatible.
Related parameters
will not be available for modification by the user.
d. Click the "OK" button,
The TabletWorks Control Panel will appear.
e. Click on the "Settings"
tab.
f. Under "Driver
Configuration": Click the drop down box and select the COM port
to which the tablet is connected.
(When this is done,
the "Enable Legacy Tablet Support" checkbox will
automatically be selected. DO NOT
DESELECT THIS CHECKBOX!!
Deselecting this checkbox could cause permanent damage to your
tabet.)
g. Click "OK". The
following message will appear:
Modified driver
settings will become effective during the next system reboot.
h. Click "OK" and restart
your computer.
6. When the computer restarts, the digitizer will be working as a mouse on
the Windows95/NT desktop.
2. Removing the TabletWorks drivers.
A. Automatic removal using a downloaded driver.
1. Click on the "Start" button.
2. Select the "Run" option.
3. Type the name and path of the downloaded file on the command line.
Example: c:\temp\tw95v51.exe
4. Click on "Setup".
5. Click on "Remove".
The drivers will be removed from your computer and you will be prompted to reboot to complete the uninstall process.
B. Automatic removal using the TabletWorks CD-ROM
1. Double-click the "My Computer" icon.
2. Double-click the "CD-ROM" icon.
3. Double-click the "Startme" icon.
4. Click on "Remove".
The drivers will be removed from your computer and you will be prompted to
reboot to complete the uninstall process.
C. Manually Removing the TabletWorks drivers from Windows95
1. From a DOS prompt, type the following commands:
deltree c:\windows\calcomp
deltree c:\windows\startm~1\programs\calcomp (CalComp tablets
only)
deltree c:\windows\startm~1\programs\summag~1 (Summagraphics
tablets only)
del c:\windows\system\ccpan32.cpl
del c:\windows\system\ccwt95.drv
del c:\windows\system\ccwtup32.dll
del c:\windows\system\cc95drv.vxd (CalComp tablets only)
del c:\windows\system\sg95drv.vxd (Summagraphics tablets
only)
del c:\windows\system\wintab.dll
del c:\windows\system\wintab32.dll
deltree c:\windows\temp\wzs*.tmp
2. Open the Registry editor.
Click on the "Start" button, select the
"Run" option, type "regedit" on the command line, and press
"Enter".
Open the following key in the Registry:
HKEY_LOCAL_MACHINE
SOFTWARE
CALCOMP
Delete the CALCOMP key from the registry.
Open the following key in the Registry:
HKEY_LOCAL_MACHINE
SYSTEM
CURRENTCONTROLSET
SERVICES
VXD
CC95DRV (CalComp tablets only)
SG95DRV (Summagraphics tablets only)
Delete the CC95DRV key from the Registry (CalComp tablets
only)
Delete the SG95DRV key from the Registry (Summagraphics
tablets only)
D. Manually Removing the TabletWorks drivers from WindowsNT
1. From a DOS prompt, type the following commands:
deltree c:\winnt\calcomp
deltree c:\winnt\startm~1\programs\calcomp (CalComp tablets
only)
deltree c:\winnt\startm~1\programs\summag~1 (Summagraphics
tablets only)
del c:\winnt\system32\ccpan32.cpl
del c:\winnt\system32\ccwt95.drv
del c:\winnt\system32\ccwtup32.dll
del c:\winnt\system32\cc95drv.vxd (CalComp tablets only)
del c:\winnt\system32\sg95drv.vxd (Summagraphics tablets
only)
del c:\winnt\system32\wintab.dll
del c:\winnt\system32\wintab32.dll
deltree c:\winnt\temp\wzs*.tmp
2. Open the Registry editor.
Click on the "Start" button, select the
"Run" option, type "regedt32" on the command line, and press
"Enter".
Open the following key in the Registry:
HKEY_LOCAL_MACHINE
SOFTWARE
CALCOMP
Delete the CALCOMP key from the registry.
Open the following key in the Registry:
HKEY_LOCAL_MACHINE
SYSTEM
CURRENTCONTROLSET
SERVICES
CC95DRV (SG95DRV for summagraphics tablets)
Delete the CC95DRV key from the Registry (CalComp tablets
only)
Delete the SG95DRV key from the Registry (Summagraphics
tablets only)
|
|